Computer Room Fire Suppression

- Oktober 16, 2017

Room : Server Room Fire Suppression Remodel Interior Planning ...
photo src: bagsjar.com

Automatic fire suppression systems control and extinguish fires without human intervention. Examples of automatic systems include fire sprinkler system, gaseous fire suppression, and condensed aerosol fire suppression. When fires are extinguished in the early stages loss of life is minimal since 93% of all fire-related deaths occur once the fire has progressed beyond the early stages.


Fire Protection in a Data Centre - YouTube
photo src: www.youtube.com


Maps, Directions, and Place Reviews



Types of automatic systems

Today there are numerous types of Automatic Fire Suppression Systems and standards for each one. Systems are as diverse as the many applications. In general, however, Automatic Fire Suppression Systems fall into two categories: engineered and pre-engineered systems.

  • Engineered Fire Suppression Systems are design specific and most commonly used for larger installations where the system is designed for a particular application. Examples include large marine and land vehicle applications, server rooms, public and private buildings, industrial paint lines, dip tanks and electrical switch rooms. Engineered systems use a number of gaseous or solid agents with many of them being specifically formulated. Some are even stored as a liquid and discharged as a gas.
  • Pre-Engineered Fire Suppression Systems use pre-designed elements to eliminate the need for engineering work beyond the original product design. Typical industrial solutions use a wet or dry chemical agent, such as potassium carbonate or monoammonium phosphate (MAP), to protect relatively smaller spaces such as distribution boards, battery rooms, engine bays, wind turbines, hazardous goods and other storage areas. A number of residential designs have also emerged that typically employ water mist and target retrofit applications.

Computer Room Fire Suppression Video



Components

By definition, an automatic fire suppression system can operate without human intervention. To do so it must possess a means of detection, actuation and delivery. In many systems, detection is accomplished by mechanical or electrical means. Mechanical detection uses fusible-link or thermo-bulb detectors. These detectors are designed to separate at a specific temperature and release tension on a release mechanism. Electrical detection uses heat detectors equipped with self-restoring, normally-open contacts which close when a predetermined temperature is reached. Remote and local manual operation is also possible. Actuation usually involves either a pressurized fluid and a release valve, or in some cases an electric pump. Delivery is accomplished by means of piping and nozzles. Nozzle design is specific to the agent used and coverage desired.


Computer & Server rooms, Projecten - DSPA.nl
photo src: www.dspa.nl


Extinguishing agents

In the early days, water was the exclusive fire suppression agent. Although still used today, water has limitations. Most notably, its liquid and conductive properties can cause as much property damage as fire itself.


Room : Awesome Server Room Fire Suppression Nice Home Design Photo ...
photo src: bagsjar.com


Health and Environmental Concerns

Despite their effectiveness, chemical fire extinguishing agents are not without disadvantages. In the early 20th century, carbon tetrachloride was extensively used as a dry cleaning solvent, a refrigerant and as a fire extinguishing agent. In time, it was found carbon tetrachloride could lead to severe health effects. From the mid-1960s Halon 1301 was the industry standard for protecting high-value assets from the threat of fire. Halon 1301 had many benefits as a fire suppression agent; it is fast-acting, safe for assets and required minimal storage space. Halon 1301's major drawbacks are that it depletes atmospheric ozone and is potentially harmful to humans. Since 1987, some 191 nations have signed The Montreal Protocol on Substances That Deplete the Ozone Layer. The Protocol is an international treaty designed to protect the ozone layer by phasing out the production of a number of substances believed to be responsible for ozone depletion. Among these were halogenated hydrocarbons often used in fire suppression. As a result, manufacturers have focused on alternatives to Halon 1301 and Halon 1211 (halogenated hydrocarbons). A number of countries have also taken steps to mandate the removal of installed Halon systems. Most notably these include Germany and Australia, the first two countries in the world to require this action. In both of these countries complete removal of installed Halon systems has been completed except for a very few essential-use applications. The European Union is currently undergoing a similar mandated removal of installed Halon systems.


Automatic fire suppression - Wikiwand
photo src: www.wikiwand.com


History

The first fire extinguisher patent was issued to Alanson Crane of Virginia on Feb. 10, 1863. The first fire sprinkler system was patented by H.W. Pratt in 1872. But the first practical automatic sprinkler system was invented in 1874 by Henry S. Parmalee of New Haven, CT. He installed the system in a piano factory he owned.


Aero-K Fire Suppression Systems/Peripherals, Inc. - Denver ...
photo src: www.thebluebook.com


Modern systems

Since the early 1990s manufacturers have successfully developed safe and effective Halon alternatives. These include DuPont's FM-200, American Pacific's Halotron, FirePro's FPC Compound and 3M's Novec 1230 Fire Protection Fluid. Generally, the Halon replacement agents available today fall into two broad categories, in-kind (gaseous extinguishing agents) or not in-kind (alternative technologies). In-kind gaseous agents generally fall into two further categories, halocarbons and inert gases. Not in-kind alternatives include such options as water mist or the use of early warning smoke detection systems.

Source of the article : Wikipedia



EmoticonEmoticon

 

Start typing and press Enter to search